/
/
/
You are here: Home » Products » Petroleum Analysis Instrument » Flash Point Tester » DSHD-261-1 Semi-Automatic Pensky-Martens Closed Cup Flash Point Tester

Product Category

loading

Share to:

DSHD-261-1 Semi-Automatic Pensky-Martens Closed Cup Flash Point Tester

Automatic temperature control and ignition.
Highly cost effective
  • Range: 40~300℃
  • Standards: ASTM D93, GB/T 261
Quantity:

Product Description

Summary

This instrument is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens closed cup method and ASTM D93 Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester.

 


 

Technical Data Sheet

I. Main technical features
1. Single chip microcomputer control technique.LCD screen displays.English man-machine interaction interface.The heating power is continuously step-less adjustable.The rate of heating up is exact.Easy setting for parameters.
2. The LCD screen has prompting menu,prompting input operation interface.It shows the setted parameters,real-time temperatures and other test parameters.Press the “record”button when the flash point appears.The screen will show and reserve the flash point.
3. The structure is newly design and small.Stainless steel table-board looks clean and beautiful.It can be used as long as equipped with gas or other civilian fuels.It is easy to use and test results exact.

SN. Item Parameter
1  Power supply: AC 220V±10%, 50 Hz;
2  Heating device
2.1  Furnace power  is; itsis  600 W, made of SiC materials
2.2  Heating power adjustable range  0 W~600W
3  Sample temperature rising rate  Procedure A ï¼š(5~8 )℃/min; Procedure B:(1~1.5)℃/minï¼›Automatically control
4  Electric stirring device
4.1  Stirring motor  BYGH101stepping motor
4.2  Driving mode  Flexible axle
4.3  Stirring blade specification  8 mm×40 mm
5  Stirring speed As per the requirement of GB/T261-2008
5.1  Procedure A;  90 RPM~120 RPM
5.2  Procedure B;  250±10 RPM
6  Standard oil cup  As per the requirement of GB/T261-2008
6.1  Inner diameter  50.7 mm~50.8 mm
6.2  Depth  55.7 mm~56.0 mm
6.3  Depth of marked line in the oil cup  33.9 mm~34.3 mm
6.4  Oil sample cubage  About 70 ml
7  Flame application device
7.1  Gas source  Gas (or other civilian fuel,the same below)
7.2  Aperture of flame application device  0.8 mm
8  Thermometer Pt100
9  Ambient temperature  ≤35℃
10  Relative humidity  ≤85ï¼…
11  Total power consumption  Not more than 650 W

Previous: 
Next: 
WhatsApp:+86-13286053265
Tel: 86-756-8305811  Email: admin@dshing.com  
Copyright  2016 Dshing Instrument Co.,Ltd. All rights reserved.    Site Map   Hot Links